Our UL approved hook up wire,lead wires and equipment wires are manufactured in a variety of material, size and designs to meet rigid industrial and government specifications. Used extensively for both electrical and electronic equipment where applications range from inter-connection circuits to internal wiring of computers and data processing equipment etc.
Technical Data:
UL Style No. | Application | Temperature Rating | ||
---|---|---|---|---|
Air(°C) | Oil(°C) | Wet(°C) | ||
1015 | Internal wiring of appliances | 105 | 80 | |
1028 | Insulated wire of appliances | 105 | 60 | |
1283 | Insulated wire for internal wiring | 105 | ||
1500 | Insulated wire for internal wiring | 105 | ||
10070 | Insulated wire for Computers & Electronics | 105 | ||
1275 | Insulated wire for internal wiring of refrigerating equipment |
105 | 60 | 60 |
1345 | Insulated wire for internal wiring | 105 | 60 | 75 |
Conductor (AWG) | 24 | 22 | 20 | 18 | 16 | 14 | 12 | 10 | 8 |
UL Style 1015 | |||||||||
---|---|---|---|---|---|---|---|---|---|
Conductor Area (sq mm) | 0.20 | 0.35 | 0.50 | 0.80 | 1.30 | 2.00 | 3.50 | 5.00 | 8.00 |
Thickness of Insulation(mm) | 0.76 | 0.76 | 0.76 | 0.76 | 0.76 | 0.76 | 0.76 | 0.76 | 1.15 |
Diameter over insulation(mm) | 2.30 | 2.50 | 2.60 | 2.90 | 3.20 | 3.60 | 4.10 | 4.70 | 6.30 |
UL Style 1345 | ||||||||
---|---|---|---|---|---|---|---|---|
Conductor Area (sq mm) | 0.20 | 0.35 | 0.50 | 0.80 | 1.30 | 2.00 | 3.50 | 5.00 |
Thickness of Insulation(mm) | 0.80 | 0.80 | 0.80 | 0.80 | 0.80 | 0.80 | 0.80 | 0.80 |
Diameter over insulation(mm) | 2.30 | 2.50 | 2.60 | 2.90 | 3.20 | 3.60 | 4.10 | 4.70 |
UL Style 1275 | |||||
---|---|---|---|---|---|
Conductor Area (sq mm) | 0.80 | 1.30 | 2.00 | 3.50 | 5.00 |
Thickness of Insulation(mm) | 1.60 | 1.60 | 1.60 | 1.60 | 1.60 |
Diameter over insulation(mm) | 4.40 | 4.70 | 5.10 | 5.60 | 6.20 |
UL Style 1028 | ||||||||
---|---|---|---|---|---|---|---|---|
Conductor Area (sq mm) | 0.35 | 0.50 | 0.80 | 1.30 | 2.00 | 3.50 | 5.00 | 8.00 |
Thickness of Insulation(mm) | 1.15 | 1.15 | 1.15 | 1.15 | 1.15 | 1.15 | 1.15 | 1.15 |
Diameter over insulation(mm) | 3.10 | 3.20 | 3.50 | 3.80 | 4.20 | 4.70 | 5.30 | 6.60 |
UL Style 1500 | ||||||||
---|---|---|---|---|---|---|---|---|
Conductor Area (sq mm) | 0.20 | 0.35 | 0.50 | 0.80 | 1.30 | 2.00 | 3.50 | 5.00 |
Thickness of Insulation(mm) | 0.85 | 0.85 | 0.85 | 0.85 | 0.85 | 0.85 | 0.85 | 0.85 |
Diameter over insulation(mm) | 2.40 | 2.60 | 2.70 | 3.00 | 3.30 | 3.70 | 4.20 | 4.80 |
UL Style 1500 | ||||||
---|---|---|---|---|---|---|
Conductor Area (sq mm) | 0.80 | 1.30 | 2.00 | 3.50 | 5.00 | 8.00 |
Thickness of Insulation(mm) | 0.76 | 0.76 | 0.76 | 0.76 | 0.76 | 0.76 |
Diameter over insulation(mm) | 2.80 | 3.10 | 3.50 | 4.00 | 4.60 | 6.60 |
Flame Retardant Heat Resistant Upto105°C Single Core Unsheated Copper Cables For Working Voltage up to 1100 Volts
REFERENCE STANDARDS
Conductor: Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking.
Insulation: Specially formulated grade of PVC compound is capable of withstanding higher conductor temperatures with flame retardant properties. A rating of 105°C with FR properties enables the cable to withstand overloads without compromising safety. The insulation is resistant to boiling water, steam and vapours to prevent aging and cracking in practical usage in kitchens, bathrooms, damp walls, chemical industries etc.
Marking: The Cable are printed with generic marking ELKAY – FRHR
Color: Skin colouring in various colour like Red, Yellow, Blue, Black, Green
Packing: 90 mts. length in attractive cartoons.
Sizes, Dimensions and Rating | |||||||
---|---|---|---|---|---|---|---|
Normal Area of Conductor | Number/Nom. Dia. | Number/Nom. Dia. For Unilay | Insulation Thickness (Nom.) | Approx. Overall Diameter | Current Carrying Amps. |
Resistance (Max.) per km | |
Sq.mm. | mm. | mm. | mm. | mm. | Concealed | Casing | @20°C Ohms. |
1.0 | 14/.3 | 19/0.26 | 0.7 | 2.8 | 11 | 12 | 18.10 |
1.5 | 22/.3 | 19/0.32 | 0.7 | 3.1 | 13 | 16 | 12.10 |
2.5 | 36/.3 | 37/0.29 | 0.8 | 3.8 | 18 | 22 | 7.41 |
4.0 | 56/.3 | 37/0.37 | 0.8 | 4.4 | 24 | 29 | 4.61 |
6.0 | 84/.3 | 61/0.35 | 0.8 | 5.0 | 31 | 37 | 3.30 |
Additional Properties | ||||
---|---|---|---|---|
Test | Specification | FRHR Typical Value | FRPVC Typical Value | Ordinary PVC Typical Value |
Critical Oxygen Index | ASTM-D 2863 | >29 | >29 | >22 |
Temperature Index | ASTM-D 2863 & BICC Hand Book ChapterNo. 6 | >250°C | >250°C | >200°C |
Smoke Density | ASTM-D 2843 | <80% | <80% | <90% |
Acid Gas Generation | IEC 754-1 | <20% | <20% | <40% |
Flammability | IEC 332-1 | Flame to extinguish with in 30 sec | Flame to extinguish with in 30 sec | Flame to extinguish with in 60 sec |
Ageing | IS 5831 | At 136°C for 7 Days | At 80°C for 7 Days | At 80°C for 7 Days |
Flame Retardant PVC Insulated Single Core Unsheated Flexible Copper Cable Having High Current Rating For Working Voltage up to 1100 Volts.
REFERENCE STANDARDS
Conductor: Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking.
Insulation: Specially formulated grade of Flame Retardant PVC compound is used which restricts the spread of flame in the fire situation and also give high dielectric strength making “ELKAY” cables ideal for conduit wiring. The smoke emitted by the burning cables is also less as compare to general cables.
Marking: The Cable are printed with generic marking ELKAY – Flame Guard
Color: Skin colouring in various colour like Red, Yellow, Blue, Black, Greens
Packing: 90 mts. length in attractive cartoons.
Sizes, Dimensions and Rating | |||||||
---|---|---|---|---|---|---|---|
Normal Area of Conductor | Number/Nom. Dia. | Number/Nom. Dia. For Unilay | Insulation Thickness (Nom.) | Approx. Overall Diameter | Current Carrying Amps. |
Resistance (Max.) per km | |
Sq.mm. | mm. | mm. | mm. | mm. | Concealed | Casing | @20°C Ohms. |
1.0 | 14/.3 | 19/0.26 | 0.7 | 2.8 | 11 | 12 | 18.10 |
1.5 | 22/.3 | 19/0.32 | 0.7 | 3.1 | 13 | 16 | 12.10 |
2.5 | 36/.3 | 37/0.29 | 0.8 | 3.8 | 18 | 22 | 7.41 |
4.0 | 56/.3 | 37/0.37 | 0.8 | 4.4 | 24 | 29 | 4.61 |
6.0 | 84/.3 | 61/0.35 | 0.8 | 5.0 | 31 | 37 | 3.30 |
Additional Properties | |||
---|---|---|---|
Test | Specification | FRPVC Typical Value | Ordinary PVC Typical Value |
Critical Oxygen Index | ASTM-D 2863 | >29 | >22 |
Temperature Index | ASTM-D 2863 & BICC Hand Book ChapterNo. 6 | >250°C | >200°C |
Smoke Density | ASTM-D 2843 | <80% | <90% |
Acid Gas Generation | IEC 754-1 | <20% | <40% |
Flammability | IEC 332-1 | Flame to extinguish with in 30 sec | Flame to extinguish with in 60 sec |
Zero Halogen, Flame Retardant, Low Smoke, Single Core Unsheated Copper Cables For Working Voltage up to 1100 Volts.
REFERENCE STANDARDS
Conductor: Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking.
Insulation: Specially formulated grade of Halogen Free Flame Retardant compound is used. The performance of the Cable in fire situation is exceptionally good.The insulation does not melt, drip or spread the fireconditions. The smoke is negligible, transparent and non-toxic.
Marking: The Cable are printed with generic marking ELKAY – ZHFR
Color: Skin colouring in various colour like Red, Yellow, Blue, Black, Green
Packing: 90 mts. length in attractive cartoons.
Sizes, Dimensions and Rating | |||||||
---|---|---|---|---|---|---|---|
Normal Area of Conductor | Number/Nom. Dia. | Number/Nom. Dia. For Unilay | Insulation Thickness (Nom.) | Approx. Overall Diameter | Current Carrying Amps. |
Resistance (Max.) per km | |
Sq.mm. | mm. | mm. | mm. | mm. | Concealed | Casing | @20°C Ohms. |
1.0 | 14/.3 | 19/0.26 | 0.7 | 2.8 | 11 | 12 | 18.10 |
1.5 | 22/.3 | 19/0.32 | 0.7 | 3.1 | 13 | 16 | 12.10 |
2.5 | 36/.3 | 37/0.29 | 0.8 | 3.8 | 18 | 22 | 7.41 |
4.0 | 56/.3 | 37/0.37 | 0.8 | 4.4 | 24 | 29 | 4.61 |
6.0 | 84/.3 | 61/0.35 | 0.8 | 5.0 | 31 | 37 | 3.30 |
Additional Properties | |||
---|---|---|---|
Test | Specification | FRPVC Typical Value | Ordinary PVC Typical Value |
Critical Oxygen Index | ASTM-D 2863 | >29 | >22 |
Temperature Index | ASTM-D 2863 & BICC Hand Book ChapterNo. 6 | >250°C | >200°C |
Smoke Density | ASTM-D 2843 | <80% | <90% |
Acid Gas Generation | IEC 754-1 | <20% | <40% |
Flammability | IEC 332-1 | Flame to extinguish with in 30 sec | Flame to extinguish with in 60 sec |
We offer a wide range of electrical copper power cables for all domestic, commercial and industrial uses. All cables comply with the relevant British Standards.We can supply all standard PVC/XLPE underground cables and house wiring cables.
Technical Data:
Nominal Cross Sectional Area (sq.mm.) |
Min. no of wires |
Radial Thickness of Insulation (mm) |
Overall Diameter (mm) |
---|---|---|---|
1.0 | 1 | 0.6 | 2.8 |
1.5 | 1 | 0.7 | 3.3 |
1.5 | 6 | 0.7 | 3.5 |
2.5 | 1 | 0.8 | 3.9 |
2.5 | 6 | 0.8 | 4.2 |
4.0 | 6 | 0.8 | 4.8 |
6.0 | 6 | 0.8 | 5.4 |
10.0 | 6 | 1.0 | 6.8 |
16.0 | 6 | 1.0 | 8.0 |
25.0 | 6 | 1.2 | 9.8 |
35.0 | 6 | 1.2 | 11.0 |
50.0 | 15 | 1.4 | 13.0 |
70.0 | 15 | 1.4 | 15.0 |
95.0 | 15 | 1.6 | 17.0 |
120.0 | 30 | 1.6 | 19.0 |
150.0 | 30 | 1.8 | 21.0 |
185.0 | 30 | 2.0 | 23.5 |
240.0 | 51 | 2.2 | 26.5 |
Nominal Cross Sectional Area (sq.mm.) |
Min. no of wires |
Radial Thickness Insulation(mm) | Overall Diameter (mm) |
|
---|---|---|---|---|
Insulation (mm) | Sheath (mm) | |||
1.0 | 1 | 0.6 | 0.8 | 4.5 |
1.5 | 1 | 0.7 | 0.8 | 4.9 |
2.5 | 1 | 0.8 | 0.8 | 5.8 |
4.0 | 6 | 0.8 | 0.9 | 6.8 |
6.0 | 6 | 0.8 | 0.9 | 7.4 |
10.0 | 6 | 1.0 | 0.9 | 8.8 |
16.0 | 6 | 1.0 | 1.0 | 10.5 |
25.0 | 6 | 1.2 | 1.1 | 12.5 |
35.0 | 6 | 1.2 | 1.1 | 13.5 |
Nominal Cross Sectional Area (sq.mm.) |
Min. no of wires |
Radial Thickness | Overall Diameter |
Earth Continuity Conductor Cross Section |
|
---|---|---|---|---|---|
Insulation (mm) | Sheath (mm) | ||||
1.0 | 1 | 0.6 | 0.9 | 4.7×8.6 | 1.0 |
1.5 | 1 | 0.7 | 0.9 | 5.4×9.6 | 1.0 |
2.5 | 1 | 0.8 | 1.0 | 6.2×11.5 | 1.5 |
4.0 | 6 | 0.8 | 1.0 | 7.2×13.0 | 1.5 |
6.0 | 6 | 0.8 | 1.1 | 8.0×15.0 | 2.5 |
10.0 | 6 | 1.0 | 1.2 | 9.6×19.0 | 4.0 |
16.0 | 6 | 1.0 | 1.3 | 11.0×22.0 | 6.0 |
Nominal Cross Sectional Area (sq.mm.) |
Min. no of wires |
Radial Thickness | Overall Diameter |
Earth Continuity Conductor Cross Section |
|
---|---|---|---|---|---|
Insulation (mm) | Sheath (mm) | ||||
1.0 | 1 | 0.6 | 0.9 | 4.7×8.6 | 1.0 |
1.5 | 1 | 0.7 | 0.9 | 5.4×9.6 | 1.0 |
2.5 | 1 | 0.8 | 1.0 | 6.2×11.5 | 1.5 |
4.0 | 6 | 0.8 | 1.0 | 7.2×13.0 | 1.5 |
6.0 | 6 | 0.8 | 1.1 | 8.0×15.0 | 2.5 |
10.0 | 6 | 1.0 | 1.2 | 9.6×19.0 | 4.0 |
16.0 | 6 | 1.0 | 1.3 | 11.0×22.0 | 6.0 |
Nominal Cross Sectional Area (sq.mm.) |
Min. no of wires |
Radial Thickness | Overall Diameter |
|
---|---|---|---|---|
Insulation (mm) | Sheath (mm) | |||
0.75 (Flat) | 0.21 | 0.6 | 0.8 | 5.2×7.6 |
0.5 | 0.21 | 0.6 | 0.8 | 7.0 |
0.75 | 0.21 | 0.6 | 0.8 | 7.6 |
1.0 | 0.21 | 0.6 | 0.8 | 8.0 |
1.25 | 0.21 | 0.7 | 0.8 | 8.6 |
1.5 | 0.26 | 0.7 | 0.8 | 9.0 |
2.5 | 0.26 | 0.8 | 1.0 | 11.0 |
0.75 | 0.21 | 0.6 | 0.8 | 8.0 |
1.0 | 0.21 | 0.6 | 0.8 | 8.4 |
1.25 | 0.21 | 0.7 | 0.9 | 9.4 |
1.5 | 0.26 | 0.7 | 0.9 | 9.8 |
2.5 | 0.26 | 0.8 | 1.1 | 12.0 |
0.75 | 0.21 | 0.6 | 0.8 | 8.6 |
1.0 | 0.21 | 0.6 | 0.9 | 9.4 |
1.5 | 0.26 | 0.7 | 1.0 | 11.0 |
2.5 | 0.26 | 0.8 | 1.1 | 13.0 |