Our UL approved hook up wire,lead wires and equipment wires are manufactured in a variety of material, size and designs to meet rigid industrial and government specifications. Used extensively for both electrical and electronic equipment where applications range from inter-connection circuits to internal wiring of computers and data processing equipment etc.

Technical Data:

  • Product: Appliance Wiring material
  • Subject: UL 758, UL 1581, UL 83
  • Voltage: 600V
  • Conductor: Bare Copper or Tinned Copper
  • Insulation: PVC
  • Core: Single Core
UL Style No. Application Temperature Rating
Air(°C) Oil(°C) Wet(°C)
1015 Internal wiring of appliances 105 80
1028 Insulated wire of appliances 105 60
1283 Insulated wire for internal wiring 105
1500 Insulated wire for internal wiring 105
10070 Insulated wire for Computers & Electronics 105
1275 Insulated wire for internal wiring
of refrigerating equipment
105 60 60
1345 Insulated wire for internal wiring 105 60 75
Conductor (AWG) 24 22 20 18 16 14 12 10 8
UL Style 1015
Conductor Area (sq mm) 0.20 0.35 0.50 0.80 1.30 2.00 3.50 5.00 8.00
Thickness of Insulation(mm) 0.76 0.76 0.76 0.76 0.76 0.76 0.76 0.76 1.15
Diameter over insulation(mm) 2.30 2.50 2.60 2.90 3.20 3.60 4.10 4.70 6.30
UL Style 1345
Conductor Area (sq mm) 0.20 0.35 0.50 0.80 1.30 2.00 3.50 5.00
Thickness of Insulation(mm) 0.80 0.80 0.80 0.80 0.80 0.80 0.80 0.80
Diameter over insulation(mm) 2.30 2.50 2.60 2.90 3.20 3.60 4.10 4.70
UL Style 1275
Conductor Area (sq mm) 0.80 1.30 2.00 3.50 5.00
Thickness of Insulation(mm) 1.60 1.60 1.60 1.60 1.60
Diameter over insulation(mm) 4.40 4.70 5.10 5.60 6.20
UL Style 1028
Conductor Area (sq mm) 0.35 0.50 0.80 1.30 2.00 3.50 5.00 8.00
Thickness of Insulation(mm) 1.15 1.15 1.15 1.15 1.15 1.15 1.15 1.15
Diameter over insulation(mm) 3.10 3.20 3.50 3.80 4.20 4.70 5.30 6.60
UL Style 1500
Conductor Area (sq mm) 0.20 0.35 0.50 0.80 1.30 2.00 3.50 5.00
Thickness of Insulation(mm) 0.85 0.85 0.85 0.85 0.85 0.85 0.85 0.85
Diameter over insulation(mm) 2.40 2.60 2.70 3.00 3.30 3.70 4.20 4.80
UL Style 1500
Conductor Area (sq mm) 0.80 1.30 2.00 3.50 5.00 8.00
Thickness of Insulation(mm) 0.76 0.76 0.76 0.76 0.76 0.76
Diameter over insulation(mm) 2.80 3.10 3.50 4.00 4.60 6.60

Flame Retardant Heat Resistant PVC Insulated Cables

Flame Retardant Heat Resistant Upto105°C Single Core Unsheated Copper Cables For Working Voltage up to 1100 Volts

REFERENCE STANDARDS

  • INTERNATIONAL: BS 6004, BS 6500, DINVDE 0281-3
  • NATIONAL: IS 694, IEC 227

Conductor: Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking.

Insulation: Specially formulated grade of PVC compound is capable of withstanding higher conductor temperatures with flame retardant properties. A rating of 105°C with FR properties enables the cable to withstand overloads without compromising safety. The insulation is resistant to boiling water, steam and vapours to prevent aging and cracking in practical usage in kitchens, bathrooms, damp walls, chemical industries etc.

Marking: The Cable are printed with generic marking ELKAY – FRHR

Color: Skin colouring in various colour like Red, Yellow, Blue, Black, Green

Packing: 90 mts. length in attractive cartoons.

Sizes, Dimensions and Rating
Normal Area of Conductor Number/Nom. Dia. Number/Nom. Dia. For Unilay Insulation Thickness (Nom.) Approx. Overall Diameter Current
Carrying Amps.
Resistance (Max.) per km
Sq.mm. mm. mm. mm. mm. Concealed Casing @20°C Ohms.
1.0 14/.3 19/0.26 0.7 2.8 11 12 18.10
1.5 22/.3 19/0.32 0.7 3.1 13 16 12.10
2.5 36/.3 37/0.29 0.8 3.8 18 22 7.41
4.0 56/.3 37/0.37 0.8 4.4 24 29 4.61
6.0 84/.3 61/0.35 0.8 5.0 31 37 3.30
Additional Properties
Test Specification FRHR Typical Value FRPVC Typical Value Ordinary PVC Typical Value
Critical Oxygen Index ASTM-D 2863 >29 >29 >22
Temperature Index ASTM-D 2863 & BICC Hand Book ChapterNo. 6 >250°C >250°C >200°C
Smoke Density ASTM-D 2843 <80% <80% <90%
Acid Gas Generation IEC 754-1 <20% <20% <40%
Flammability IEC 332-1 Flame to extinguish with in 30 sec Flame to extinguish with in 30 sec Flame to extinguish with in 60 sec
Ageing IS 5831 At 136°C for 7 Days At 80°C for 7 Days At 80°C for 7 Days

Flame Retardant PVC Insulated Cables

Flame Retardant PVC Insulated Single Core Unsheated Flexible Copper Cable Having High Current Rating For Working Voltage up to 1100 Volts.

REFERENCE STANDARDS

  • INTERNATIONAL: BS 6004, BS 6500, DINVDE 0281-3
  • NATIONAL: IS 694, IEC 227

Conductor: Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking.

Insulation: Specially formulated grade of Flame Retardant PVC compound is used which restricts the spread of flame in the fire situation and also give high dielectric strength making “ELKAY” cables ideal for conduit wiring. The smoke emitted by the burning cables is also less as compare to general cables.

Marking: The Cable are printed with generic marking ELKAY – Flame Guard

Color: Skin colouring in various colour like Red, Yellow, Blue, Black, Greens

Packing: 90 mts. length in attractive cartoons.

Sizes, Dimensions and Rating
Normal Area of Conductor Number/Nom. Dia. Number/Nom. Dia. For Unilay Insulation Thickness (Nom.) Approx. Overall Diameter Current
Carrying Amps.
Resistance (Max.) per km
Sq.mm. mm. mm. mm. mm. Concealed Casing @20°C Ohms.
1.0 14/.3 19/0.26 0.7 2.8 11 12 18.10
1.5 22/.3 19/0.32 0.7 3.1 13 16 12.10
2.5 36/.3 37/0.29 0.8 3.8 18 22 7.41
4.0 56/.3 37/0.37 0.8 4.4 24 29 4.61
6.0 84/.3 61/0.35 0.8 5.0 31 37 3.30
Additional Properties
Test Specification FRPVC Typical Value Ordinary PVC Typical Value
Critical Oxygen Index ASTM-D 2863 >29 >22
Temperature Index ASTM-D 2863 & BICC Hand Book ChapterNo. 6 >250°C >200°C
Smoke Density ASTM-D 2843 <80% <90%
Acid Gas Generation IEC 754-1 <20% <40%
Flammability IEC 332-1 Flame to extinguish with in 30 sec Flame to extinguish with in 60 sec

Zero Halogen Flame Retardent Low Smoke, Insulated Cables

Zero Halogen, Flame Retardant, Low Smoke, Single Core Unsheated Copper Cables For Working Voltage up to 1100 Volts.

REFERENCE STANDARDS

  • INTERNATIONAL: BS 4066-1 & 3, BS6724, VDE 0207
  • NATIONAL: IEC 332-1 & 3, IEC 754-1

Conductor: Bright annealed bare copper of high electrolytic grade drawn to fine strands, multi strands bunched together rope shaped wire for uniformity of conductor dia, resistance, dimensions and flexibility etc. The diameter of the conductor is so uniform that strands do not get cut when stripping the insulation thus conductor gives perfect conductivity which eliminates spot heating and sparking.

Insulation: Specially formulated grade of Halogen Free Flame Retardant compound is used. The performance of the Cable in fire situation is exceptionally good.The insulation does not melt, drip or spread the fireconditions. The smoke is negligible, transparent and non-toxic.

Marking: The Cable are printed with generic marking ELKAY – ZHFR

Color: Skin colouring in various colour like Red, Yellow, Blue, Black, Green

Packing: 90 mts. length in attractive cartoons.

Sizes, Dimensions and Rating
Normal Area of Conductor Number/Nom. Dia. Number/Nom. Dia. For Unilay Insulation Thickness (Nom.) Approx. Overall Diameter Current
Carrying Amps.
Resistance (Max.) per km
Sq.mm. mm. mm. mm. mm. Concealed Casing @20°C Ohms.
1.0 14/.3 19/0.26 0.7 2.8 11 12 18.10
1.5 22/.3 19/0.32 0.7 3.1 13 16 12.10
2.5 36/.3 37/0.29 0.8 3.8 18 22 7.41
4.0 56/.3 37/0.37 0.8 4.4 24 29 4.61
6.0 84/.3 61/0.35 0.8 5.0 31 37 3.30
Additional Properties
Test Specification FRPVC Typical Value Ordinary PVC Typical Value
Critical Oxygen Index ASTM-D 2863 >29 >22
Temperature Index ASTM-D 2863 & BICC Hand Book ChapterNo. 6 >250°C >200°C
Smoke Density ASTM-D 2843 <80% <90%
Acid Gas Generation IEC 754-1 <20% <40%
Flammability IEC 332-1 Flame to extinguish with in 30 sec Flame to extinguish with in 60 sec

Single Core Conduit Cables

We offer a wide range of electrical copper power cables for all domestic, commercial and industrial uses. All cables comply with the relevant British Standards.We can supply all standard PVC/XLPE underground cables and house wiring cables.

Technical Data:

  • Single Core Conduit Cables: Solid or stranded plain copper conductor, PVC insulated
  • Single Core Double Insulated Cables/Twin and Earthed Cables/Three Core and Earthed Cables: Solid and Stranded, plain copper conductor.
  • Normal Duty Flexible Cords: Flat twin, Circular twin, Circular 3 core, Circular 4core.
  • Light Flexible Core: Flat twin, Circular twin, Circular 3 core, Circular 4 core,plain copper flexible conductor, PVC insulated, PVC sheathed.
Nominal Cross
Sectional Area
(sq.mm.)
Min. no of
wires
Radial Thickness
of Insulation
(mm)
Overall
Diameter (mm)
1.0 1 0.6 2.8
1.5 1 0.7 3.3
1.5 6 0.7 3.5
2.5 1 0.8 3.9
2.5 6 0.8 4.2
4.0 6 0.8 4.8
6.0 6 0.8 5.4
10.0 6 1.0 6.8
16.0 6 1.0 8.0
25.0 6 1.2 9.8
35.0 6 1.2 11.0
50.0 15 1.4 13.0
70.0 15 1.4 15.0
95.0 15 1.6 17.0
120.0 30 1.6 19.0
150.0 30 1.8 21.0
185.0 30 2.0 23.5
240.0 51 2.2 26.5
Nominal Cross
Sectional Area
(sq.mm.)
Min. no of
wires
Radial Thickness Insulation(mm) Overall
Diameter (mm)
Insulation (mm) Sheath (mm)
1.0 1 0.6 0.8 4.5
1.5 1 0.7 0.8 4.9
2.5 1 0.8 0.8 5.8
4.0 6 0.8 0.9 6.8
6.0 6 0.8 0.9 7.4
10.0 6 1.0 0.9 8.8
16.0 6 1.0 1.0 10.5
25.0 6 1.2 1.1 12.5
35.0 6 1.2 1.1 13.5

Two Core Conduit Cables

Nominal Cross
Sectional Area
(sq.mm.)
Min. no of
wires
Radial Thickness Overall
Diameter
Earth Continuity
Conductor Cross
Section
Insulation (mm) Sheath (mm)
1.0 1 0.6 0.9 4.7×8.6 1.0
1.5 1 0.7 0.9 5.4×9.6 1.0
2.5 1 0.8 1.0 6.2×11.5 1.5
4.0 6 0.8 1.0 7.2×13.0 1.5
6.0 6 0.8 1.1 8.0×15.0 2.5
10.0 6 1.0 1.2 9.6×19.0 4.0
16.0 6 1.0 1.3 11.0×22.0 6.0

Three Core Conduit Cables

Nominal Cross
Sectional Area
(sq.mm.)
Min. no of
wires
Radial Thickness Overall
Diameter
Earth Continuity
Conductor Cross
Section
Insulation (mm) Sheath (mm)
1.0 1 0.6 0.9 4.7×8.6 1.0
1.5 1 0.7 0.9 5.4×9.6 1.0
2.5 1 0.8 1.0 6.2×11.5 1.5
4.0 6 0.8 1.0 7.2×13.0 1.5
6.0 6 0.8 1.1 8.0×15.0 2.5
10.0 6 1.0 1.2 9.6×19.0 4.0
16.0 6 1.0 1.3 11.0×22.0 6.0

Normal Duty Flexible Cords

Nominal Cross
Sectional Area
(sq.mm.)
Min. no of
wires
Radial Thickness Overall
Diameter
Insulation (mm) Sheath (mm)
0.75 (Flat) 0.21 0.6 0.8 5.2×7.6
0.5 0.21 0.6 0.8 7.0
0.75 0.21 0.6 0.8 7.6
1.0 0.21 0.6 0.8 8.0
1.25 0.21 0.7 0.8 8.6
1.5 0.26 0.7 0.8 9.0
2.5 0.26 0.8 1.0 11.0
0.75 0.21 0.6 0.8 8.0
1.0 0.21 0.6 0.8 8.4
1.25 0.21 0.7 0.9 9.4
1.5 0.26 0.7 0.9 9.8
2.5 0.26 0.8 1.1 12.0
0.75 0.21 0.6 0.8 8.6
1.0 0.21 0.6 0.9 9.4
1.5 0.26 0.7 1.0 11.0
2.5 0.26 0.8 1.1 13.0